<!-- ngg_resource_manager_marker -->		<a id="scroll-to-top" href="#" title="Scroll to Top">Top</a>
		<script>
jQuery(function($) {
$('a[rel^="compose"]').prettyPhoto({ show_title: false, overlay_gallery: false, social_tools: '<div class="facebook"><iframe src="http://www.facebook.com/plugins/like.php?href={location_href}&amp;send=false&amp;layout=button_count&amp;width=450&amp;show_faces=false&amp;action=like&amp;colorscheme=light&amp;font&amp;height=21" scrolling="no" frameborder="0" style="border:none; overflow:visible; width:150px; height:21px;" allowTransparency="true"></iframe></div>' });
});
</script>
<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HKL AG &#187; DCDC Hybrid</title>
	<atom:link href="https://www.hkl-ag.de/thema/dcdc-hybrid/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.hkl-ag.de</link>
	<description></description>
	<lastBuildDate>Sun, 20 May 2018 18:23:36 +0000</lastBuildDate>
	<language>de-DE</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	
	<item>
		<title>DCDC Hybrid</title>
		<link>https://www.hkl-ag.de/dcdc-hybrid/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=dcdc-hybrid</link>
		<comments>https://www.hkl-ag.de/dcdc-hybrid/#comments</comments>
		<pubDate>Tue, 11 Jun 2013 09:12:10 +0000</pubDate>
		<dc:creator><![CDATA[HKL AG]]></dc:creator>
				<category><![CDATA[Informationen und Datenblätter]]></category>
		<category><![CDATA[DCDC]]></category>
		<category><![CDATA[DCDC Hybrid]]></category>
		<category><![CDATA[Energiekosten]]></category>
		<category><![CDATA[Kälte]]></category>
		<category><![CDATA[Klima]]></category>

		<guid isPermaLink="false">http://www2.hkl-ag.de/?p=144</guid>
		<description><![CDATA[<p>&#8220;DCDC Hybrid&#8221; ist ein Seitenkühler, der speziell für den Einsatz in Rechenzentren konzipiert wurde. Das System nutzt primär einen Wasser-Kühlkreislauf, der das Rechenzentrum mittels eines  Freikühlers und der Außenluft effektiv herabkühlt. Wird die Außentemperaturgrenze von 15°C überschritten, schaltet sich der sekundäre Kältemittel-Kühlkreislauf zu und sorgt zuverlässig für das Erreichen der gewünschten Endtemperatur. Kompakt: Beide Kühlsysteme [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.hkl-ag.de/dcdc-hybrid/">DCDC Hybrid</a> appeared first on <a rel="nofollow" href="https://www.hkl-ag.de">HKL AG</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p><a href="http://www.hkl-ag.de/wp-content/uploads/2014/06/hkl-dcdc-hybrid.jpg" style="background-image:none; padding:0;" rel="compose[144]"><img class="size-medium wp-image-883 alignright" alt="DCDC Hybrid Seitenkühler" src="http://www.hkl-ag.de/wp-content/uploads/2014/06/hkl-dcdc-hybrid-300x240.jpg" width="300" height="240" /></a>&#8220;DCDC Hybrid&#8221; ist ein Seitenkühler, der speziell für den Einsatz in Rechenzentren konzipiert wurde. Das System nutzt primär einen Wasser-Kühlkreislauf, der das Rechenzentrum mittels eines  Freikühlers und der Außenluft effektiv herabkühlt. Wird die Außentemperaturgrenze von 15°C überschritten, schaltet sich der sekundäre Kältemittel-Kühlkreislauf zu und sorgt zuverlässig für das Erreichen der gewünschten Endtemperatur. Kompakt: Beide Kühlsysteme finden in demselben Gehäuse Platz &#8211; so kann etwa die Hälfte der für herkömmliche Anlagen nötigen Stellfläche eingespart werden.</p>
<p>Das duale Kühlsystem des &#8220;DCDC Hybrid&#8221; trägt den steigenden Energiekosten und dem immer wichtiger werdenden Umweltschutz Rechnung. Die Technologie ist weltweit einzigartig und stellt die Weichen für weitere Anwendungen von derart energieoptimierten Kühllösungen.</p>
<p>Der finanzielle Vorteil beim Einsatz dieses Systems ist signifikant – die jährlichen Energiekosten lassen sich so um einen beträchtlichen Anteil reduzieren. Kostenersparnis, zuverlässiger Betrieb  und Umweltschutz gehen bei diesem innovativen Produkt Hand in Hand.</p>
<h2>Technische Daten des DCDC Hybrid Seitenkühlers</h2>

<table id="tablepress-2" class="tablepress tablepress-id-2">
<thead>
<tr class="row-1 odd">
	<th class="column-1"><div>Name</div></th><th class="column-2"><div>DCDC S</div></th><th class="column-3"><div>DCDC S</div></th><th class="column-4"><div>DCDC S</div></th><th class="column-5"><div>DCDC R</div></th><th class="column-6"><div>DCDC R</div></th><th class="column-7"><div>DCDC R</div></th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">kW</td><td class="column-2">10 kW</td><td class="column-3">20 kW</td><td class="column-4">30 kW</td><td class="column-5">10 kW</td><td class="column-6">20 kW</td><td class="column-7">30 kW</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Maße</td><td class="column-2">*</td><td class="column-3">*</td><td class="column-4">*</td><td class="column-5">*</td><td class="column-6">*</td><td class="column-7">*</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">KG</td><td class="column-2">260KG</td><td class="column-3">263KG</td><td class="column-4">265KG</td><td class="column-5">270KG</td><td class="column-6">280KG</td><td class="column-7">285KG</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Seitenkühler Farbe</td><td class="column-2">9005 / 7035</td><td class="column-3">9005 / 7035</td><td class="column-4">9005 / 7035</td><td class="column-5">9005 / 7035</td><td class="column-6">9005 / 7035</td><td class="column-7">9005 / 7035</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Spannung</td><td class="column-2">400V</td><td class="column-3">400V</td><td class="column-4">400V</td><td class="column-5">400V</td><td class="column-6">400V</td><td class="column-7">400V</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Redundanz</td><td class="column-2">Nein</td><td class="column-3">Nein</td><td class="column-4">Nein</td><td class="column-5">Ja</td><td class="column-6">Ja</td><td class="column-7">Ja</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lüfter im Betrieb austauschbar</td><td class="column-2">Ja</td><td class="column-3">Ja</td><td class="column-4">Ja</td><td class="column-5">Ja</td><td class="column-6">Ja</td><td class="column-7">Ja</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Ventilatoren Ausführung</td><td class="column-2">EC</td><td class="column-3">EC</td><td class="column-4">EC</td><td class="column-5">EC</td><td class="column-6">EC</td><td class="column-7">EC</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Drehzahlgeregelte Ventilatoren</td><td class="column-2">JA</td><td class="column-3">JA</td><td class="column-4">JA</td><td class="column-5">JA</td><td class="column-6">JA</td><td class="column-7">JA</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Außengerät</td><td class="column-2"></td><td class="column-3"></td><td class="column-4"></td><td class="column-5"></td><td class="column-6"></td><td class="column-7"></td>
</tr>
</tbody>
</table>
<!-- #tablepress-2 from cache -->
<p>* B 300 mm | H 2000 mm (2200 mm) | T 1000 mm (1200 mm)</p>
<p><a href="http://www.hkl-ag.de/wp-content/uploads/2014/05/HKL-DCDC-Hybrid-Seitenkühler-DE.pdf" target="_blank">IT-Klimatisierung &#8211; DCDC Hybrid Flyer in Deutsch</a><br />
<a href="http://www.hkl-ag.de/wp-content/uploads/2014/05/HKL-DCDC-Hybrid-Sidecooler-EN.pdf" target="_blank">IT-Klimatisierung &#8211; DCDC Hybrid Flyer in Englisch</a></p>
<p>The post <a rel="nofollow" href="https://www.hkl-ag.de/dcdc-hybrid/">DCDC Hybrid</a> appeared first on <a rel="nofollow" href="https://www.hkl-ag.de">HKL AG</a>.</p>
]]></content:encoded>
			<wfw:commentRss>https://www.hkl-ag.de/dcdc-hybrid/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
